Ceiling halogen operating light Ot Light

PICTURENAMEMODELUnit PriceEXW USDTECHNICAL SPECIFICATIONFEATURESDIMENSION(MM)PACKAGEG.W.(KG)Volume(m³) integral reflection operation lamp KL700/700-IIIUS$2,722Illumination:80,000-160,000LX x2(at 1m distance) 925×925×365 925×925×365  1195×915×4003cartons21.5 &

Featured Products

PICTURENAMEMODELUnit Price
EXW USD
TECHNICAL SPECIFICATIONFEATURESDIMENSION
(MM)
PACKAGEG.W.
(KG)
Volume
(m³)
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL700/700-IIIUS$2,722Illumination:80,000-160,000LX x2(at 1m distance) 925×925×365 
925×925×365  
1195×915×400
3
cartons
21.5   21.5    66.51.07
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm1.imported aluminum sheet squamulose reflector
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Color temperature:4500K±500K4.optional imported spring arm
Temperature rise:12ºC5.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC6.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:700mm ×27.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz8.dischargeable handle
Bulb voltage:AC24V Bulb power9.battery is optional
Input power:200VA ×2 
Height for installation:280-320cm 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL700/500-IIIUS$2696Illumination:80,000-160,000Lx /60,000-120,000Lx(at 1m distance) 925×925×365 
765×725×320  
1195×915×400
3
cartons
21.5     14.5     66.50.94
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm1.imported aluminum sheet squamulose reflector
Brightness adjustment:  CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Color temperature:4500K±500K4.optional imported spring arm
Temperature rise:12ºC5.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC6.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:700mm/500mm7.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz8.dischargeable handle
Bulb voltage:AC24V Bulb power9.battery is optional
Input power:200VA ×2 
Height for installation:280-320cm 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL500/500-IIIUS$2,742Illumination:60,0000-120,000LX x2(at 1m distance) 765×725×320  
765×725×320     1195×915×400
3
cartons
14.5    14.5     66.50.79
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm1.imported aluminum sheet squamulose reflector
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Color temperature:4500K±500K4.optional imported spring arm
Temperature rise:12ºC5.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC6.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:500mm ×27.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz8.dischargeable handle
Bulb voltage:AC24V Bulb power9.battery is optional
Input power:200VA ×2 
Height for installation:280-320cm 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL700-IIIUS$1,411Illumination:80,000-160,000LX (at 1m distance) 925×925×365
1195×915×400
2
cartons
21.5    510.76
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm1.imported aluminum sheet squamulose reflector
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Color temperature:4500K±500K4.optional imported spring arm
Temperature rise:12ºC5.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC6.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:700mm7.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz8.dischargeable handle
Bulb voltage:AC24V Bulb power9.battery is optional
Input power:200VA 
Height for installation:280-320cm 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL500-III
(ceiling type)
US$1,411Illumination:60,000-120,000LX (at 1m distance) 765×725×320  1195×915×4002
cartons
12.7    510.62
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm1.imported aluminum sheet squamulose reflector
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Color temperature:4500K±500K4.optional imported spring arm
Temperature rise:12ºC5.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC6.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:500mm7.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz8.dischargeable handle
Bulb voltage:AC24V Bulb power9.battery is optional
Input power:200VA 
Height for installation:280-320cm 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL500-III
(AC/DC)
US$1,774Illumination:60,000-120,000LX (at 1m distance) 
1060×710×910
1
wooden
case
1160.69
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm1.imported aluminum sheet squamulose reflector
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Color temperature:4500K±500K4.optional imported spring arm
Temperature rise:12ºC5.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC6.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:500mm7.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz8.dischargeable handle
Bulb voltage:AC24V Bulb power9.battery is optional
Input power:200VA 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lamp KL500-III
(stand type)
US$1,512Illumination:60,000-120,000LX (at 1m distance) 749×744×354  1050×705×4002
wooden
case
18   74.50.5
Facula diameter:φ100~φ280mm 
Depth of light beam:700mm 
Brightness adjustment:CPU light-dimmer1.imported aluminum sheet squamulose reflector
Shift of major and stand by lamps:automatic2.titanium main arm
Color temperature:4500K±500K3.optional imported spring arm
Temperature rise:12ºC4.OSRAM halogen bulbs
Temperature rise on the head of patient:2ºC5.automatic change to standby bulb in 1/2 second
Diameter of lamp holder:500mm6.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz7.dischargeable handle
Bulb voltage:AC24V Bulb power8.battery is optional
Input power:200VA 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lampKL600-IIUS$1,310Illumination:80,000-140,000LX (at 1m distance) 925×925×365 1195×915×4002
cartons
21.5    510.76
Facula diameter:φ100~φ280mm1.imported aluminum sheet squamulose reflector
Depth of light beam:700mm
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Temperature rise:12ºC4.automatic change to standby bulb in 1/2 second
Temperature rise on the head of patient:2ºC
Diameter of lamp holder:600mm5.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz6.dischargeable handle
Bulb voltage:AC24V Bulb power 
Input power:220VA 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lampKL600-II
(wall type)
US$1,774Illumination:80,000-140,000LX (at 1m distance) 1024×954×384  1234×954×4342
cartons
31    740.9
Facula diameter:φ100~φ280mm1.imported aluminum sheet squamulose reflector
Depth of light beam:700mm
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Temperature rise:12ºC4.automatic change to standby bulb in 1/2 second
Temperature rise on the head of patient:2ºC
Diameter of lamp holder:600mm5.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz6.dischargeable handle
Bulb voltage:AC24V Bulb power 
Input power:220VA 
Ceiling Halogen Operating Lamp Ot Light integral reflection operation lampKL600/600-IIUS$2,319Illumination:80,000-140,000LX /80,000-140,000LX(at 1m distance) 925×925×365 
925×925×365 
 1195×915×400
3
cartons
21.5   21.5    66.51.07
Facula diameter:φ100~φ280mm1.imported aluminum sheet squamulose reflector
Depth of light beam:700mm
Brightness adjustment:CPU light-dimmer2.imported polish panel
Shift of major and stand by lamps:automatic3.titanium main arm
Temperature rise:12ºC4.automatic change to standby bulb in 1/2 second
Temperature rise on the head of patient:2ºC
Diameter of lamp holder:600mm5.indicator for damaged bulb
Mains voltage:AC220V±20% 50Hz6.dischargeable handle
Bulb voltage:AC24V Bulb power 
Input power:440VA 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours